Fluid-applied restoration turns a sound but weathered roof into a warrantied, renewable system — no demolition, no landfill fees, no shutting down the building.

  • 10–20 yr renewable warranty
  • Manufacturer-certified applicators
  • Infrared moisture survey first
Typical cost reduction vs. full tear-off
60–75%Typical cost reduction vs. full tear-off
Building closure required
0 daysBuilding closure required
Warranty renews at roughly half the original cost
RecoatWarranty renews at roughly half the original cost

Restoration vs. tear-off, on your square footage

Connecticut planning ranges for budgeting only — a real number comes after the core samples and moisture survey.

Current membrane

Fluid-applied restoration$5–$7 / sq ft
$200,000 – $290,000
Full tear-off & replacement$12–$16 / sq ft
$480,000 – $640,000

$190,000+

Net capital saved

100% Yr-1

Section 179 deductible as maintenance

10–20 yrs

Renewable warranty term

Restoration is generally expensed in the year of work under Section 179 rather than depreciated over 39 years like a replacement — confirm treatment with your tax advisor. It only applies where the insulation is dry, and we will say so if it is not.

The case

Why restoration beats replacement — when it fits

A tear-off means demolition, disposal, exposure risk and disruption to everything under the roof. When the insulation is dry and the deck is sound, none of that is necessary. A fluid-applied system seals seams, flashings and the field into one monolithic membrane and carries its own manufacturer warranty.

Restoration typically costs a fraction of a full replacement, is usually treated as a maintenance expense rather than a capital project, and is renewable — a recoat at the end of term resets the warranty at a fraction of the original cost.

The honest caveat: it only works on a roof with dry insulation. We core-sample and perform a moisture survey first. If the substrate is wet, we will tell you that a coating is the wrong answer.

Good candidate

Qualifies

Sound single-ply, mod bit or metal with dry insulation, functioning drains and localised seam or flashing failures.

Replace instead

Does not qualify

Saturated insulation, failed deck, permanent ponding with no slope, or a membrane already past its structural life.

Chemistry

Coating systems we install

Silicone

The workhorse for ponding-prone roofs. Silicone shrugs off standing water and UV without becoming brittle, and it re-coats cleanly at the end of its term.

10–20 year renewable warranty · excellent ponding resistance · high solids

Acrylic

Water-based, highly reflective and cost-effective on sloped metal and sound membranes in well-drained conditions. Not the choice where water stands.

10–15 year warranty · highest reflectivity per dollar · easy recoat

Polyurethane

Tough, abrasion-resistant surface for roofs with regular foot traffic, service platforms and equipment access paths.

10–18 year warranty · superior impact and traffic resistance

Process

How a restoration runs

1. Moisture survey

Core samples and infrared scanning to confirm the insulation is dry.

2. Repairs & prep

Wet areas cut out, seams and flashings reinforced, roof power-washed and primed.

3. Base & top coat

Reinforced detail work at penetrations, then full-field coats at spec mil thickness.

4. Warranty & recoat plan

Manufacturer inspection, warranty issue, and a scheduled recoat date on file.

Next step

Get the moisture survey booked

Commercial Division

Request a commercial RFP or site audit

For facility managers, property managers, HOA boards and owners. No cost, no obligation, full photo condition report.

Your details are used only to schedule the audit and prepare pricing.

RoofingCat AI Assistant

Ask the RoofingCat AI Assistant about this page

Not sure whether to coat or replace?

We'll core the roof, run a moisture survey and give you both numbers side by side, with the honest recommendation attached.